WCS Defaults

Instead of editing distances and other parameters manually every time you build a project, these values automatically pre-populate your project settings:

1.Default tool diameter [mm]: the ruby diameter at the probe tip. Default: 6 mm.

2.Default approach distance [mm]: the distance at which the probe slows down in front of a surface. Default: 10 mm.

3.Default overtravel distance [mm]: the extra search depth past the expected surface. Default: 3 mm.

4.Default clearance height [mm]: the safe height used before the first point and after the last point. Default: 300 mm.

5.Default retraction height [mm]: the height the probe backs off to between points. Default: 75 mm.

6.Default probing linear speed [mm/s]: the touch-sensing search speed. Default: 5 mm/s.

7.Default travel linear speed [mm/s]: the linear speed in free air. Default: 40 mm/s.

8.Default travel joint speed [deg/s]: the joint speed for travel moves. Default: 20 deg/s.