Select Validate from the Wizard. The calibration data will be used to calculate the TCP (excluding robot calibration). You will then be directed to the Analyze tab of the wizard. The calculated TCP will be displayed, and some statistics will provide estimated errors for the calculated TCP.
Select Validation to display a summary and some statistics about the results. These statistics correspond to the planar errors detected by the sensor.
Tip: Taking more measurements for calibration can remarkably improve the calibration results. You can change the sensor target measurement (for example, use an 8 mm target after the default 4 mm target for a second calibration). You can also change the robot configuration to take measurements on the same point but with different joint angles (for example, using the flip and non-flip configurations).